RCD Breaker

Quick Details : Place of origin : Guangdong , China ( Mainland ) Product name : RCD breaker Type : Electric plug Color : Black/white/grey Product information : About RCD : An RCD does not provide protection against unexpected or dangerously high current (called spikes or surges) when current is...

Send InquiryChat Now

Quick Details

Place of originGuangdongChinaMainland

Product nameRCD breaker

TypeElectric plug

ColorBlack/white/grey

 

Product information

Poles

2P/3P

Frequency

50Hz~60Hz

Rated Voltage

110VAC/230VAC

Rated Current

10A/16A

In

6mA/10mA/30mA

Break Time

≤0.1S

Temperature

-20~+40±5

Cable model

1/1.5m

 

 

About RCD

An RCD does not provide protection against unexpected or dangerously high current (called spikes or surges) when current is in the usual wires in the circuit, therefore it cannot replace a fuse or protect against overheating or fire risk due to overcurrent (overload) or short circuits if the fault does not lead to current leakage. Therefore, RCDs are often used or integrated as a single product along with some kind of circuit breaker, such as a fuse or miniature circuit breaker (MCB), which adds protection in the event of excessive current in the circuit (the resulting RCD with overcurrent protection called an RCBO). RCDs also cannot detect the situation where a human accidentally touches both conductors at the same time, since the current through an expected device, an unexpected route, or a human, are indistinguishable if the current returns through the expected conductor.

 

RCDs are usually testable and resettable devices. Commonly they include a button that when pressed, safely creates a small leakage condition, and a switch that reconnects the conductors when a fault condition has been cleared. Depending upon their design, some RCDs disconnect both the energized and return conductors upon a fault, while others only disconnect the energized conductor and rely upon the return conductor being at ground (earth) potential. The former are commonly known as "double-pole" designs; the latter as "single-pole" designs. If the fault has left the return wire "floating" or not at its expected ground potential for any reason, then a single-pole RCD will leave this conductor still connected to the circuit when it detects the fault.


Hot Tags: rcd breaker, manufacturers, suppliers, factory, buy, customized, discount, low price, made in China